Flameless Electric Air Heaters

Triple Pass Accessories

Pressure Switch

Triple Pass Accessories - Pressure Switch Triple Pass Accessories - Pressure Switch

FOR 10” EXCHANGER (NOT SHOWN) -
ORDER SWITCH #004-10033
Adjustable: 0-30 psi Proof: 45 psi

FOR 13” EXCHANGER (SHOWN) -
ORDER SWITCH #004-10034
Adjustable: 0-2.9 psi Proof: 5 psi

RELAY #004-10035
Required for loads 15-25 amps

Thermocouple Assembly

Straight Opening

Exchanger A B Part Number
including 'K' Thermocouple
10" 3/4” 1-1/2” 004-10036
13" 1-1/2” 1-1/2” 004-10038

‘K’ THERMOCOUPLE PROBE ONLY - #004-10037

Flare

Exchanger   A B C D Part Number
10" Flare Only 3/4” 3” 2-1/2” 3/32” 004-10044
10" Flare & TC Port 3/4” 3” 2-1/2” 3/32” 004-10045
13” Flare Only 1-1/2” 4-3/16” 4” 1/4” 004-10046
13” Flare & TC Port 1-1/2” 4-3/16” 4” 1/4” 004-10047

‘K’ THERMOCOUPLE PROBE ONLY - #004-10037

Thermocouple Assembly

Straight Opening

Exchanger A B C D E F Part
Number
10" 1-7/32” 4-3/8” 2-1/2” 3/8” 2-3/8” 4-3/8” 004-10042
13" 2-3/16” 4-11/16” 4-1/2” 3/4” 3-11/16” 4-11/16” 004-10043

Part Number: 009-10252
(For use with 003-10027 Housing Only)

CONVECTRONICS’ REGENERATIVE BLOWER can be used as the air source for the 003-10027 Housing (13”), as the maximum pressure is 1.5 psi under normal conditions. All the other heater types operate at higher pressures and can not be used with this blower.The amount of air flow to the heater should be adjusted by venting some of the blower output into the room by means of a gate valve connected off a tee at the blower outlet.

Never throttle unwanted blower air. Dumping and bleeding air is recommended so that the blower is not over-pressured and overheated.

Use the shortest length and largest diameter piping practical to minimize friction losses and pressure drop. Excessive losses will cause motor overheating and reduced air flow.

Specifications:
• 3/4 Horsepower
• 115/230 Volt Single Phase
• Max. Flow - 84 SCFM
• Max. Pressure - 1.8 psi
• Weight – 52 Lbs.

Accessories:
• 009-10253 Pressure Gauge
  (0 - 2 psi)
• 009-10254 Input Filter
  (Recommended in dusty areas)

INDUSTRY-NET-PREFERRED-SUPPLIER-LOGO
  • Calculator
  • Standard Flow Rate (SCFM) Calculator

    Calculate the SCFM.

    Power Flowrate Calculator

    Calculate the electrical power, flow rate or temperature requirement.

    Temperature Conversion

    Fill in one value to calculate the other.

    Ohms Law Calculator

    Fill in two values to find the other two.

    Pressure Conversion

    Fill in one value to calculate the other.

    Three Phase Unit Calculator

    Fill in two values to find the 3rd.

    Single Phase Unit Calculator

    Fill in two values to find the 3rd.

    Parallel Resistance Calculator

    Calculate the total resistance in ohms of resistors that are in parallel by entering the value of each below.

    Series Resistance Calculator

    Calculate the resistance in ohms of resistors connected in series by entering the value of each.

    Copyright © 2024 Convectronics. All Rights Reserved.