Air Heaters Triple Pass Accessories Convectronics Manufactures First Class Heaters, Temperature Sensors and Precise Controls, Assists with Design and Application Needs.

HEATERS   SENSORS   CONTROLS

High Temperature Air Heater Information
Heater Style Application and Selection Guide
Single Pass Quartz Tube Heaters
Metal Shell Air Heaters
Triple Pass Housings/Elements
Accessories
Performance Characteristics
Triple Pass Flanged Housings/Elements
Triple Pass Heaters: Three Element Housing
Open Coil Convection Heaters
In-line Pipe Heaters
High Volume In-line Pipe Heaters
Power Control Module
S.C.R. Power Controls
Contactors and Controllers

Flameless Electric Air Heaters
Triple Pass Accessories

 
Pressure Switch    
FOR 10” EXCHANGER
(NOT SHOWN) - ORDER SWITCH #004-10033
Adjustable: 0-30 psi Proof: 45 psi

FOR 13” EXCHANGER (SHOWN) -
ORDER SWITCH #004-10034
Adjustable: 0-2.9 psi Proof: 5 psi

RELAY #004-10035
Required for loads 15-25 amps

           
Thermocouple Assembly - Straight Opening
Exchanger A B Part Number
including 'K' Thermocouple
10" 3/4” 1-1/2” 004-10036
13" 1-1/2” 1-1/2” 004-10038
'K' Thermocouple Probe Only - #004-10037
Click on image to enlarge    
           
Flare          
 
Exchanger   A B C D Part Number
10" Flare Only 3/4” 3” 2-1/2” 3/32” 004-10044
10" Flare & TC Port 3/4” 3” 2-1/2” 3/32” 004-10045
13” Flare Only 1-1/2” 4-3/16” 4” 1/4” 004-10046
13” Flare & TC Port 1-1/2” 4-3/16” 4” 1/4” 004-10047
'K' Thermocouple Probe Only - #004-10037
Click on image to enlarge      
   
Exchanger Junction Box Assembly  
 
Exchanger A B C D E F Part
Number
10" 1-7/32” 4-3/8” 2-1/2” 3/8” 2-3/8” 4-3/8” 004-10042
13" 2-3/16” 4-11/16” 4-1/2” 3/4” 3-11/16” 4-11/16” 004-10043
Click on image to enlarge    
     
> Back to Top    
     
Part Number: 009-10252
(For use with 003-10027 Housing Only)
  CONVECTRONICS’ REGENERATIVE BLOWER can be used as the air source for the 003-10027 Housing (13”), as the maximum pressure is 1.5 psi under normal conditions. All the other heater types operate at higher pressures and can not be used with this blower.

The amount of air flow to the heater should be adjusted by venting some of the blower output into the room by means of a gate valve connected off a tee at the blower outlet.

Never throttle unwanted blower air. Dumping and bleeding air is recommended so that the blower is not over-pressured and overheated.

Use the shortest length and largest diameter piping practical to minimize friction losses and pressure drop. Excessive losses will cause motor overheating and reduced air flow.

     

Specifications:
• 3/4 Horsepower
• 115/230 Volt Single Phase
• Max. Flow - 84 SCFM
• Max. Pressure - 1.8 psi
• Weight – 52 Lbs.

Accessories:
009-10253 Pressure Gauge
  (0 - 2 psi)
009-10254 Input Filter
  (Recommended in dusty areas)

Please click on image to enlarge    
   
Please click on image to enlarge    
> Back to Top    
     
 
Convectronics, Inc.   •   Ward Hill Industrial Park West, 111 Neck Road Haverhill, MA 01835 USA   •   978-374-7714